Battery voltage reading nonfunctional

Open

#116 opened on Jul 19, 2024

View on GitHub
 (1 comment) (0 reactions) (1 assignee)C (7 forks)auto 404
bughelp wantedstm32

Repository metrics

Stars
 (3 stars)
PR merge metrics
 (PR metrics pending)

Description

Describe the Bug The battery test (test_battery.c) hangs.

To Reproduce Steps to reproduce the behavior:

  1. pio test -e tests -f test_battery
  2. Observe that the code hangs even after trying to reset
...
[stm32wlx.cpu0] halted due to debug-request, current mode: Thread 
xPSR: 0x01000000 pc: 0x08003b8c msp: 0x20008000
** Programming Started **
Warn : Adding extra erase range, 0x08009ea0 .. 0x08009fff
** Programming Finished **
** Verify Started **
** Verified OK **
** Resetting Target **
shutdown command invoked
Testing...
If you don't see any output for the first 10 secs, please reset board (press reset button)

Expected Behavior The test code should pass. When running the example code it appears to be reading two separate values. The code is fairly old and I believe that there is some hardware conflict between the LoRa and battery code. When trying to add SysApp_Init to start the clock and RTC that's used for HAL_Delay the code returns error. The way to read the values may have changed after playing around with the LoRa firmware.

Screenshots

Example output from example_battery. Should read a constant voltage

Battery Voltage: 8295 mV
Battery Voltage: 3947 mV
Battery Voltage: 2418 mV
Battery Voltage: 8298 mV

Environment

Linux spruce 6.8.2-arch2-1 #1 SMP PREEMPT_DYNAMIC Thu, 28 Mar 2024 17:06:35 +0000 x86_64 GNU/Linux PlatformIO Core, version 6.1.7 Used ST-Link V3 MINIE

Done via remote development

Additional Context Battery tests for remote development are currently disabled and should be enabled in the stm32.yaml workflow once fixed.